The unit is simple to operate using push button controls and requires little or no training. It is calibrated to each cylinder at the touch of a button. The ultrasonic “dry” sensor requires no water or gel to ensure good transmission of the ultrasonic signal; the optional “wet” sensor to condition cylinders where thick or irregular coatings or badly pitted and rusty surfaces prevent the dry sensor from obtaining a clear signal. The sensors are housed in a magnetic applicator which ensures good contact with the surface and
allows hands-free operation.
To locate the liquid level in a vessel:
The sensor applicator is placed on the test vessel below the expected liquid level and then calibrated and all LED lights are lit on the digital unit, or the meter fully deflected on the analogue.
The sensor is then placed above the expected level – all lights extinguish.
The sensor is moved between these two points in small steps until the interface is located.
All unusual readings should be double-checked, if the same readings result we recommend that the bottle be isolated and removed for weighing; in most cases the contents will have leaked.